eans of small wedge-shaped templates. The several ways of connecting up the steps are shown in Fig. 161. That shown at A is the wrong method of tonguing the riser into the tread above. B is the correct method when they are tongued, and C the usual method. In this the riser is not tongued, the… … bad. It is sometimes used in common work to save jointing treads. B is the usual and correct method, and C is an excellent way preferred by many. Here the tread is screwed to the riser, which it slightly overhangs, slots being made for the screws, so that in case of shrinkage a little movement may…